Previous revision
firmware:changelog [2016/12/31 12:20]
Matthew Upp
firmware:changelog [2019/09/28 10:40] (current)
Matthew Upp
Line 2: Line 2:
  
 ====== Changelog ====== ====== Changelog ======
-//<wrap lo>These are not complete or official changelogs. As of this writing there isn't one. Approximate release dates will be added later</​wrap>//​ \\+//<wrap lo>These are not complete or official changelogs. As of this writing there isn't one.</​wrap>//​ \\
  
 ---- ----
  
-<​WRAP ​box 43% left>+<​WRAP ​group> 
 +<WRAP column half>
  
 ===== Motion Controller ===== ===== Motion Controller =====
 ---- ----
 +
 +==== v51 ====
 +<wrap hi>"​Pro"/​V3 Only</​wrap>​ \\
 +<wrap lo>v51 is not available for download. I prefer v50 anyways because the bed leveling probe points are further from the center of the bed. v51 for some reason probes 4 points in a small square near the center of the build plate.</​wrap>​
 +\\
 +
 +----
 +
 +==== v50 ====
 +<wrap hi>"​Pro"/​V3 Only</​wrap>​ \\
 +**[[https://​mpselectmini.com/​_media/​firmware/​motion/​mpsm_pro_-_motion_v50_-_2018-07-12.zip|v50 - Motion Controller firmware for MPSM Pro/V3]]** \\
 +\\
 +
 +----
 +
 +==== v41 ====
 +<wrap hi>V2 Only</​wrap>​ \\
 +<wrap lo>Build Date: //​2018-JAN-24 09:​31:​06//</​wrap>​ \\
 +<wrap lo>First Tested: //​2018-JAN-29//</​wrap>​ \\
 +<wrap lo>​Available for Download: //​2018-MAR-06//</​wrap>​ \\
 +- Updated Hardware Ids \\
 +     * Vendor ID: 0x2e26 \\
 +     * Product ID: 0x0200 \\
 +- Windows 10, Device Manager listed under **Ports (COM & LPT)** will now recognize the printer as "<​color #​ed1c24>​Monoprice Mini Select (COM #​)"</​color>"​ and listed under **Printers** the printer will be displayed as "<​color #​ed1c24>​Monoprice Select Mini</​color>"​. \\
 +\\
 +
 +----
 +
 +==== v40 ====
 +<wrap hi>V2 Only</​wrap>​ \\
 +<wrap lo>Build Date: //​2018-AUG-10 09:​53:​33//</​wrap>​ \\
 +<wrap lo>First Tested: //​2017-AUG-14//</​wrap>​ \\
 +<wrap lo>​Available for Download: //​2017-SEP-18//</​wrap>​ \\
 +- Modified heater runaway protection. If heating and sensor reading not changing after 30 second, will stop heating and (should) halt. (Something appears to have been happening when printing via USB that caused the nozzle temperature to continuously rise. Cause unknown but doesn'​t appear to have been a firmware bug that caused the temperature increase.) \\
 +- Fix cancel procedure. - (when pressing cancel twice during pre-heat, the printhead would start moving which required the MPSM V2 to be switched off) \\
 +- Fixed some USB compatibility issue with Linux/​MacOSX system. Cura 15.##.# and Repetier-Host working on macOS. Cura 2.# and Simplify3D on macOS may not connect. \\
 +
 +----
 +
 ==== v29 ==== ==== v29 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-NOV-03) \\ (2016-NOV-03) \\
 - Minor bug fix. \\ - Minor bug fix. \\
Line 19: Line 60:
 \\ \\
  
 +----
  
 ==== v28 ==== ==== v28 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-OCT-28) \\ (2016-OCT-28) \\
 - Unknown \\ - Unknown \\
 \\ \\
  
 +----
  
 ==== v27 ==== ==== v27 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-OCT-04) \\ (2016-OCT-04) \\
-Option to use a different type of thermistor on the heat bed. Added a few more thermistors options to the list of potential replacement thermistors. \\ +Option to use a different type of thermistor on the heat bed. Added a few more thermistors options to the list of potential replacement thermistors. ​\\ 
 +[[:​extended_g-code_table#​m561_-_heat_bed_thermistor_type|M561 - Heat bed thermistor type]] \\ "M561 B P1" or "M561 B P0" ​\\
 \\ \\
  
 +----
  
 ==== v26 ==== ==== v26 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-SEPT-08) \\ (2016-SEPT-08) \\
-- Add: M561 - Change thermistor type \\+- Add: [[:​extended_g-code_table#​m561_-_change_thermistor_type|M561 - Change thermistor type]] \\ "M561 P1" or "M561 P0" ​\\
 - Fixed file reading error, software will retry open and read file again, but file pointer set to 0 by mistake causing printing progress jump back to 0. \\ - Fixed file reading error, software will retry open and read file again, but file pointer set to 0 by mistake causing printing progress jump back to 0. \\
-- Enabled [[main_board_cooling_fan|fan header]] for main board cooling \\+- Enabled [[:​mainboard_cooling_fan|fan header]] for main board cooling \\
 \\ \\
  
 +----
  
 ==== v24 ==== ==== v24 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (no date or download available) \\ (no date or download available) \\
-- Unknown \\+- Unknown \\D
 \\ \\
  
 +
 +----
  
 ==== v22 ==== ==== v22 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-AUG-03) \\ (2016-AUG-03) \\
 - Reopen file if there was a SD card read error. \\ - Reopen file if there was a SD card read error. \\
Line 52: Line 105:
 \\ \\
  
 +----
  
 ==== v20 ==== ==== v20 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-JUL-20) \\ (2016-JUL-20) \\
 - Unknown \\ - Unknown \\
 \\ \\
  
 +----
  
 ==== v18 ==== ==== v18 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-JUL-01) \\ (2016-JUL-01) \\
-Unknown ​\\+M303 (PID Autotune) connection lose bug fixed. If command M303 was sent printer froze or lost connection requiring the printer to be power cycled. 
 +- PID Autotune still didn't work well. \\
 \\ \\
  
  
 ==== v15 ==== ==== v15 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-JUN-15) \\ (2016-JUN-15) \\
 - Unknown - Unknown
 \\ \\
  
 +----
  
 ==== v14 ==== ==== v14 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-JUN-09 - date first made available) \\ (2016-JUN-09 - date first made available) \\
 - Unknown \\ - Unknown \\
 \\ \\
 +
 +----
  
 </​WRAP>​ </​WRAP>​
  
 +<WRAP column half>
  
  
-<WRAP box 46% right> 
  
 ===== UI Controller ===== ===== UI Controller =====
 ---- ----
 ==== v42 ==== ==== v42 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-SEPT-07) \\ (2016-SEPT-07) \\
 - Solved heated bed setting (unknown exactly what the fix did) \\ - Solved heated bed setting (unknown exactly what the fix did) \\
 - Add the ability for the user to upload a custom Web UI. \\ - Add the ability for the user to upload a custom Web UI. \\
-- M566 - Rename cache file \\+[[:​extended_g-code_table#​m566_-_rename_cache_file|M566 - Rename cache file]] \\
 \\ \\
  
 +----
  
 ==== v41 ==== ==== v41 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-AUG-16 - unreleased) \\ (2016-AUG-16 - unreleased) \\
 - Added web-socket interface, use browser to access printer using WebSocket. This will allow faster communication with the printer using a web browser. \\ - Added web-socket interface, use browser to access printer using WebSocket. This will allow faster communication with the printer using a web browser. \\
 \\ \\
  
 +----
  
 ==== v39 ==== ==== v39 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-AUG-03) \\ (2016-AUG-03) \\
 - Bug fix - Bug fix
Line 104: Line 172:
 \\ \\
  
 +----
  
 ==== v38 ==== ==== v38 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-JUL-21) \\ (2016-JUL-21) \\
 - Changed cursor color to red. \\ - Changed cursor color to red. \\
 \\ \\
  
 +----
  
 ==== v37 ==== ==== v37 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-JUL-01) \\ (2016-JUL-01) \\
 - Updated Web UI - added buttons and temperature control / monitors. Version 33 only had an option to upload g-code. \\ - Updated Web UI - added buttons and temperature control / monitors. Version 33 only had an option to upload g-code. \\
 \\ \\
  
 +----
  
 ==== v36 ==== ==== v36 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-Jun-15) \\ (2016-Jun-15) \\
 - Unknown \\ - Unknown \\
 \\ \\
  
 +----
  
 ==== v34 ==== ==== v34 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-Jun-11) \\ (2016-Jun-11) \\
 - Bugs fixes \\ - Bugs fixes \\
 \\ \\
 +
 +----
  
 ==== v33 ==== ==== v33 ====
 +<wrap hi>V1 Only</​wrap>​ \\
 (2016-Jun-09) \\ (2016-Jun-09) \\
 - WiFi made available \\ - WiFi made available \\
-- First implementation of Web UI \\+[[:​wifi#​accessing_web_ui|First implementation of Web UI]] \\
  
 +
 +</​WRAP>​
 </​WRAP>​ </​WRAP>​
  
firmware/changelog.1483186811.txt.gz · Last modified: 2016/12/31 12:20 by Matthew Upp